Southbend S36D Bedienungsanleitung Seite 18

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 17
I
NSTALLATION
S
S
ERIES
R
ESTAURANT
R
ANGES
P
AGE
18
OF
40 O
WNER
S
M
ANUAL
1191904
REV
1
(11/10)
S
TEP
3:
A
TTACH
F
LUE
R
ISER AND
S
HELF
A
SSEMBLY
Place the flue riser assembly on the range as shown on the appropriate diagram below.
1. Slide the flue riser assembly over the bayonets until it bottoms out, as shown below.
2. Secure ends of flue riser assembly with two (2) 1/4-20 x 3/4 hex head bolts, flat washers and lockwashers.
3. Attach the shelf assembly (if ordered) to the flue riser assembly with 1/4-20 x 3/4 hex head bolts, flat washers
and lockwashers.
Figure 6
Installation of Flue Riser and Shelf Assembly
Single-Oven Models Dual-Oven Models
S
TEP
4:
E
LECTRICAL
C
ONNECTION
Wiring diagrams are located on the rear of the range. Be sure that the input voltage and phase match the
requirements shown on the serial plate (see Figure 1 on page 3).
Ranges are factory-equipped either with a power cord or with one or two two-pole terminal blocks (one for each oven),
located behind cover plate(s) located on the rear of the range. To connect the supply wires, remove the appropriate
cover plate. Route the supply wires and the grounding wire through the strain relief fitting to the terminal block. Insert
the supply wires, one each, into the two poles of the terminal block and tighten the screws. Insert the ground wire into
the grounding lug and tighten the screw. Re-attach the cover plate.
Three phase ranges are wired as above, using only two supply wires. The third wire is not used and must be properly
terminated.
All ranges are shipped wired as specified by factory order. Conversion between single-phase and three-phase can be
accomplished by referring to phase loading and line amperes chart on wiring diagram for wire size and ampere
requirements.
S
TEP
5:
G
AS
C
ONNECTION
If this equipment is being installed at over 610 meters altitude and that information was not specified when ordered,
contact the appropriate authorized Southbend Service Representative or the Southbend Service Department. Failure
to install with proper orifice sizing will result in poor performance and may void the warranty.
Seitenansicht 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 39 40

Kommentare zu diesen Handbüchern

Keine Kommentare